Scope and parts
Part 1 covers the single-bolt joint, or a group that can be reduced to a single bolt, with metric steel bolts subjected to static or fatigue loading from axial and transverse loads and bending moments. Part 2 extends the method to multi-bolt joints, such as flanges and large joints.
The edition of Part 1 in use today is the 2015 edition: some formulas and tables have changed compared with earlier versions, so it is advisable to state the edition in the calculation report.

The method step by step
The calculation is organised in steps, labelled R0 to R13. If a check is not satisfied, you go back and change the diameter, the property class or the tightening method.
- R0: initial estimate of the nominal diameter
- R1: tightening factor αA, the ratio between maximum and minimum assembly preload
- R2: minimum clamp load against slipping, joint opening or loss of sealing
- R3: resilience of the bolt and clamped parts and load factor Φ
- R4: preload loss due to embedding and thermal effects
- R5 and R6: minimum and maximum assembly preload
- R7 and R8: bolt check at assembly and in service
- R9: fatigue check
- R10: surface pressure under the head and nut
- R11: minimum length of engagement
- R12: safety against slipping and shearing
- R13: tightening torque
Preload, tightening factor and load factor
The bolt in tension and the clamped parts in compression behave like two springs in series. The minimum assembly preload must cover the required clamp load, the share of the external load that relieves the clamped parts and the loss due to embedding.
The maximum preload is obtained by multiplying the minimum by αA. With yield-controlled or angle-controlled tightening αA is close to 1; with a torque wrench it is higher, and with impact wrenches higher still.
The load factor Φ depends on the resilience values and on the point where the load is introduced into the clamped parts. A low Φ means that the bolt sees only a small part of the alternating load, which is very favourable for fatigue.
Data needed for the calculation
- Axial, transverse and bending service loads, with maximum and minimum values if variable
- Geometry: diameter, pitch, clamp length, bearing and hole diameters
- Materials of the clamped parts and permissible surface pressure
- Bolt property class and thread type
- Coefficients of friction in the thread and under the head
- Tightening method and number of interfaces, to estimate embedding
Common mistakes
- Using a torque from a table without knowing the actual friction
- Ignoring embedding in joints with many interfaces or painted surfaces
- Checking only static tension when the load is alternating
- Overlooking the pressure under the head on aluminium or soft materials
- Forgetting joint opening when a bending moment is present
Related standards
The mechanical properties of bolts are defined by ISO 898-1, those of nuts by ISO 898-2. For steel structures, bolted connections are also checked to EN 1993-1-8, while for railway vehicles VDI 2230 is often used alongside EN 12663. Ranieri — Servizi di ingegneria carries out the check of a bolted joint to VDI 2230 with a calculation report, and on the website you will find a free tightening torque calculator.
Frequently asked questions
What is the tightening factor αA?
It is the ratio between the maximum and the minimum preload achieved at assembly with a given tightening method. It accounts for the scatter of friction and of the tool: the less precise the method, the higher αA and the more the bolt has to be oversized.
Is VDI 2230 mandatory?
No, it is a guideline of the Association of German Engineers and not a harmonised standard. However, it is the recognised reference for the calculation of bolted joints and is referred to in many specifications and product standards.
How is the tightening torque calculated according to VDI 2230?
The torque is derived from the assembly preload, the thread geometry and the coefficients of friction in the thread and under the head. The permissible preload is usually the one that brings the equivalent stress to 90% of the bolt's minimum yield strength.
What is the difference between Part 1 and Part 2?
Part 1 deals with the single-bolt joint or joints that can be reduced to it. Part 2 covers multi-bolt joints, where loads are distributed unevenly and more complete models are needed.
Summary for information only: the requirements are those of the official text of the standard in its current edition, available from the standards bodies. Ranieri — Servizi di ingegneria covers the mechanical side and does not carry out work reserved to members of a professional register.